Product code: YT-99738
Available quantity Available
| Parameter | Specification |
|---|---|
| Brand | YATO |
| Model | YT-99738 |
| Series | GRF |
| Type | Liquid-fuel air heater with flue connection |
| Heating output | 20 kW |
| Manufacturer-stated max. heating area | up to 200 m²* |
| Airflow | 600 m³/h |
| Fuel | Diesel / kerosene |
| Fuel tank capacity | 38 L |
| Fuel consumption | 1.65 kg/h ** |
| Air pressure | 0.38 bar |
| Temperature control | Yes |
| Thermostat | Manual |
| Display | LED |
| Flame failure sensor | Yes |
| Flue/exhaust connection | Yes |
| Exhaust pipe | Not included |
| Power supply | 220–240 V AC |
| Frequency | 50 Hz |
| Fan motor power | 230 W |
| Hot-air outlet diameter | 235 mm |
| Protection rating | IPX4 |
| Power cable length | Approx. 1.25–1.3 m*** |
| Dimensions | 840 × 490 × 690 mm |
| Weight | 21.3 kg |
*The stated 200 m² is a manufacturer-provided maximum reference value. Actual heating performance depends on room volume, insulation, outdoor temperature, ventilation and heat loss.
YATO YT-99738 is a portable 20 kW liquid-fuel air heater with provision for exhausting combustion gases, designed for heating working areas and construction drying applications. It can be connected to a suitable exhaust system, distinguishing it from conventional direct-fired diesel heaters.
The heater delivers up to 600 m³/h of airflow, while the manufacturer specifies a maximum heating area of up to 200 m². A large 38-litre fuel tank enables extended operation without frequent refuelling.
The manually adjustable thermostat allows the required temperature to be selected, while the LED display shows the current ambient temperature. A built-in flame failure sensor provides additional operating safety.
The YT-99738 features a durable metal housing, transport wheels and a handle, making the 21.3 kg unit easier to move between working areas.
A key feature of the YT-99738 is its provision for connection to a suitable combustion-gas exhaust system.
This allows exhaust gases to be routed away from the heated area when the heater and flue system are correctly installed and operated according to the manufacturer's instructions.
The exhaust/flue pipe is not included.
The combustion-gas exhaust system must be correctly selected, installed and routed to a safe location in accordance with the manufacturer's instructions.
The availability of a flue connection does not mean that the heater can be operated in any enclosed space without ventilation. Adequate combustion-air supply and ventilation must still be provided, and all manufacturer-specified fire-safety requirements must be observed.